NSF-61 vs. NSF-372: What’s the Difference for Certified Flanges?

NSF-61 and NSF-372 usually appear side by side on certified flange spec sheets. And they are often written as one single designation, which is NSF-61/372. But they are two separate standards.  In this article, we explain what each one evaluates, how the two work together on a flange, and what the difference means when a certified flange is specified or verified.

NSF-61 vs. NSF-372

Factor NSF/ANSI/CAN 61 NSF/ANSI/CAN 372
Full title Drinking Water System Components: Health Effects Drinking Water System Components: Lead Content
What it evaluates Whether contaminants that leach or migrate from a product into drinking water exceed acceptable levels How much lead the product’s wetted surfaces contain
How it is tested Laboratory extraction testing that simulates contact with drinking water A weighted-average lead calculation across wetted components, followed by verification testing
Limit Contaminant limits set by the standard 0.25% maximum weighted average for most components; 0.2% for solder and flux
Products covered Products, components, and materials that contact drinking water Pipes, fittings and flanges, valves, gaskets, coatings, faucets, filters, meters, and more
Legal basis Referenced in the drinking water rules of 49 states The lead-free definition in the federal Safe Drinking Water Act
Relationship Requires products to be evaluated to NSF-372, unless exempted under the Safe Drinking Water Act Usually paired with a leaching standard such as NSF-61
Origin First published in 1988, together with NSF-60 Became its own standard in 2010; lead content was in NSF-61 Annex G from December 2008
Sources: NSF/ANSI/CAN 61 testing and certification; NSF/ANSI/CAN 372 technical requirements; NSF Safe Drinking Water Act requirements; NSF survey of ASDWA members.

What NSF-61 Evaluates

The NSF-61 standard sets health-effects criteria for products, components, and materials that contact drinking water. Its core question is whether contaminants that leach or migrate from a product into the water exceed acceptable levels. For flanges, that means the flange body, the gaskets and seals, and any coatings.
The standard organizes its requirements into numbered sections by product type. Certification follows the same seven steps regardless of section, and NSF maintains it annually through regular audits and surveillance. Our guide to the NSF/ANSI/CAN 61 certification process for flanges walks through the steps.
SectionProduct CategoryRelevance to Flanges
Section 4Pipes and related productsIncludes fittings and flanges
Section 5Barrier materialsIncludes paints and coatings
Section 6Joining and sealing materialsIncludes gaskets and seals
Sections 7 to 9Process media, mechanical devices, and mechanical plumbing devicesNot flange categories

Source: NSF/ANSI/CAN 61 testing and certification and API International’s NSF-61 guide.

What NSF-372 Evaluates

NSF-372 addresses lead content only. It does not evaluate whether lead or any other contaminant leaches out of a product. Instead, it measures how much lead is physically present in the wetted surfaces and compares it with the federal lead-free limit. That limit is a 0.25% weighted average for most components and 0.2% for solder and flux.
The NSF-372 standard sets out a weighted-average formula for calculating lead content before testing, along with the procedures used to verify compliance. NSF-372 lists coatings, valves, pipes, gaskets, fittings and flanges, faucets, water filters, water softeners, reverse osmosis systems, ultraviolet reactors, and water meters among the products covered. Our guide to NSF-372 technical requirements explains the calculation in more detail.

How NSF-61 and NSF-372 Work Together on a Flange

A flange is not just the flange body. NSF-372 calculates lead content as a weighted average across every wetted component in a complete flange assembly. It uses each component’s surface area and lead content. A stainless steel flange body with a leaded brass fitting in the wetted path does not pass or fail on the body alone. NSF-61 evaluates the same parts for what they could leach. Its 2024 edition also added PFAS testing for fluoropolymer materials, which are common in flange gaskets and seals.

Part of the Assembly

NSF-61

NSF-372

Flange body (stainless or carbon steel)

Covered as a pipe and related product, which includes fittings and flanges

Counted in the weighted average; 304L and 316L alloys typically carry negligible lead

Gaskets and seals

Covered as joining and sealing materials; fluoropolymers also face PFAS testing

Gaskets are among the products NSF lists as covered

Coatings

Covered as barrier materials, which include paints and coatings

Coatings are among the products NSF lists as covered

Other wetted components, such as brass fittings

Evaluated for what they could leach into drinking water

A leaded component affects the weighted average for the whole assembly

The standards are also linked in listings. NSF identifies three kinds of listing that indicate compliance with the federal lead-free requirement.
ListingWhat It Indicates
NSF/ANSI/CAN 372The product was verified directly for lead content
NSF/ANSI/CAN 61NSF-61 requires products to be evaluated to NSF-372, unless exempted under the Safe Drinking Water Act
NSF/ANSI 14 for potable waterNSF/ANSI 14 requires evaluation to NSF-61 and therefore to NSF-372

Source: NSF Safe Drinking Water Act requirements.

Why NSF-61 and NSF-372 Are Separate Standards

Lead content was not always its own standard. NSF added Annex G to NSF-61 in December 2008 to set a 0.25% weighted-average lead-content methodology. It became the standalone NSF/ANSI 372 in 2010, and Annex G was retired from NSF-61 in 2013. NSF notes that NSF-372 certification demonstrates lead-content compliance only. And NSF-61 Annex G demonstrated both lead content and lead leaching. That is part of why certified flanges today are listed to both standards. Our history of NSF/ANSI/CAN 60 and 61 blog post covers the full timeline.
YearMilestone
December 2008Annex G is added to NSF-61, setting a 0.25% weighted-average lead-content methodology
2010The lead-content methodology becomes its own standard, NSF/ANSI 372
2011The Safe Drinking Water Act redefines “lead free” nationwide at 0.25%, with a compliance date of January 2014
2013Annex G is retired from NSF-61
January 2022NSF-61 Section 3.6 takes effect, requiring lead-content verification testing on essentially every certified product, subject to Safe Drinking Water Act exemptions
2024NSF-61 adds expanded PFAS testing for fluoropolymer materials, with a compliance deadline of January 1, 2028

Sources: API International’s NSF-61 guide and NSF-372 guide; EPA lead-free rule.

What Federal and State Rules Say

NSF-372 follows the federal lead-free definition in the Safe Drinking Water Act, as it was established by the EPA’s September 2020 final rule. The rule calls for third-party certification by accredited certification bodies. It means a manufacturer’s own statement is not sufficient. EPA’s compliance advisory notes that manufacturers with 10 or more employees must obtain third-party certification, while smaller manufacturers and custom fabricated products may also self-certify.
NSF-61 reaches flanges through state rules. NSF’s survey found that 49 U.S. states require drinking water system components to comply with or be certified to NSF-61. The survey tracks NSF-60 and NSF-61 adoption and does not report NSF-372 separately. NSF-372 is tied to NSF-61 through the federal rule. Our guide to how states specify NSF/ANSI/CAN 60, 61, and 372 covers the survey in detail. And our guide to compliance vs. certification explains why third-party certification matters.

How to Verify Both Standards on a Flange

Certification to both standards can be checked in NSF’s public database of certified products and systems, which can be searched by manufacturer and product line. The table below lists what to confirm.

Check

What to Confirm

Manufacturer

The company name appears in NSF’s listings

Product line, size, and material grade

The flange being purchased is covered, not only the product family

Standards

The listing shows NSF/ANSI/CAN 61 and NSF/ANSI/CAN 372

Certifier

The certification comes from an accredited certifier, as the state or project requires

Documentation

The supplier can provide the listing details or certificate on request

Conclusion

Products certified to NSF-61 must also be evaluated to NSF-372. That is why certified flanges are listed to both and described as NSF-61/372. Every flange in API International’s CleanLine product family is certified to both NSF/ANSI/CAN 61 and NSF/ANSI/CAN 372. See our official NSF listing for the complete list of certified products. Explore our online product catalog to view our full range of flanges, or contact us for custom machining of nonstandard sizes and configurations. Get connected with a dedicated sales representative today, or call 503.692.3800.

Frequently Asked Questions

What is the difference between NSF-61 and NSF-372?

NSF-61 covers the full range of chemicals a product might leach into drinking water. NSF-372 covers one specific thing: a maximum weighted-average lead content of 0.25%. The two are usually required together, not as alternatives to each other.

Does a flange need both NSF-61 and NSF-372?

In nearly all cases, yes. Products certified to NSF-61 must also be evaluated to NSF-372, with limited exemptions under the Safe Drinking Water Act. Certified flanges are therefore listed to both standards.

Is NSF-372 a leaching test?

No. NSF-372 measures how much lead is present in a product’s wetted surfaces. NSF-61 evaluates what may leach out of the product.

What is the lead limit under NSF-372?

The limit is a 0.25% maximum weighted average for most components and 0.2% for solder and flux. It comes from the lead-free definition in the Safe Drinking Water Act.

Are any flanges exempt from the lead-free requirement?

Products used exclusively for non-potable service, products labeled “Not for use with water for human consumption,” and certain items such as fire hydrants and gate valves 2 inches or larger are exempt. Most flanges used in drinking water systems are not exempt. See our guide to the Safe Drinking Water Act and lead-free flanges.

Why are NSF-61 and NSF-372 separate standards?

Lead content was part of NSF-61 as Annex G from December 2008. It became the standalone NSF-372 in 2010, and Annex G was retired in 2013. NSF-372 now covers lead content only, while NSF-61 covers the broader leaching and health-effects evaluation.

Which NSF listings show a product meets the federal lead-free requirement?

NSF identifies products listed to NSF/ANSI/CAN 372, NSF/ANSI/CAN 61, or NSF/ANSI 14 for potable water. NSF-61 requires evaluation to NSF-372, and NSF/ANSI 14 requires evaluation to NSF-61 and therefore NSF-372, unless a product is exempt.

How can certification to both standards be verified?

NSF’s public certified products database can be searched by manufacturer and product line. The listing should cover the specific flange by size and material grade, and show both standards. API International’s CleanLine certification can be checked through our official NSF listing.

Related Products